Lancet Needles Mold Assembly
The system processes the Lancet Needles of diameter 0.8mm and 0.45 mm. The needles are first singulated individually and precisely and then accurately placed on a transfer table. The needles are then picked up by a high-speed, high-precision SCARA Robot, which transfers them to the Molding station and accurately placed on a mold short.
The system achieves multiple pick-up and place of up to 16 components, easy product conversion.
The system incorporates Vision Inspection module to inspect the following quality parameters: Good mold, Pins OK, Extra Pin, Missing Pin, Short mold, Empty mold, Invalid. |